Jump to the main text

Hitachi Appliances, Inc.

Hitachi

Specifications of Scroll Compressor for Railway Applications

Constant Speed

Comp. Type Horizontal Type Vertial Type
Model G350DL G500DL G750EL G1000EL G503DH
Nominal Rating HP 3.5 5.0 7.5 10.0 5.0
Frequency Hz 50 60 50 60 50 60 50 60 50 60
Cooling Capacity*1 kW 10.6 12.8 14.7 17.7 23.8 29.0 29.5 35.7 15.1 18.2
Motor Input kW 3.70 4.40 5.20 6.10 7.90 9.60 9.56 11.58 4.70 5.70
Displacement cm3/rev 56 80 128 160 80
Piping Connection Suction(inch) 3/4 3/4 1 1 3/4
Discharge(inch) 1/2 1/2 3/4 3/4 1/2
Oil liter 1.5 1.5 3.5 3.5 1.5
Net Weight kg 35 35 89 91 36
Power Supply AC 3Phase A dot - dot
C
D dot dot dot dot -
CE Compliance* dot dot -

Inverter Controlled Compressors

Comp. Type Horizontal Type
Model G501DLV
Nominal Rating HP 5.0
Frequency Hz 50 60
Cooling Capacity*1 kW - 14.7
Motor Input kW - 5.00
Displacement cm3/rev 64.2
Piping Connection Suction(inch) 3/4
Discharge(inch) 1/2
Oil Charge liter 1.5
Net Weight kg 37
Power
Supply
AC 3Phase A
C
D dot
CE Compliance*
*1
W × 0.860 = Kcal/h
  1. The aforementioned piping connection sizes show the piping size to be connected on suction and discharge of the compressors by brazing.
  2. The compressors are driving by two-pole motors mounted with the same shaft and with rotation of 2.880min-1 (2,880rpm) at 50Hz and 3,470min-1(3,470rpm) at 60Hz, at the rated votage.
  3. Net weight invludes oil charge.
  4. Power Supply
    A: 200V-50Hz, 200V-60Hz
    C: 380V-60Hz
    D: 380V-50Hz, 440V-60Hz
  5. Models marked with dot are available.
    Models marked with are available on request or under development.
  6. *Power supply of CE compliance model is only D: 380V-50Hz.
  7. : Models marked with comply with CE standards at the customer side after setting up inverters in the compressors.
  8. The performance data are based on the following conditions(temperature is based on central point) :
Refrigerant R407C
Evaporationg Temperature 7.2 (45)
Condensing Temperature 54.4 (130)
Liquid Temperature 44.4 (112)
Entering Gas Temperature to Condenser 21.7 (71)
Ambient Temperature 35.0 (95)
Power Supply Rated Voltage

Operating frequency range of Inverter compressor(G501DLV): 60-100Hz.
However, there is a limit to the pressure range when operating at 80-100Hz.